OR_EQUIP_ABLATION
Description:
This table stores details about ablation usage during surgery.

Primary Key
Column Name Ordinal Position
RECORD_ID 1
LINE 2

Column Information
Name Type Discontinued?
1 RECORD_ID VARCHAR No
The unique identifier (.1 item) for the line record.
2 LINE INTEGER No
The line number for the information associated with this record. Multiple pieces of information can be associated with this record.
3 ABLATION_REGION_C_NAME VARCHAR No
This column stores the area of the body where the ablation was performed.
May contain organization-specific values: Yes
No Entries Defined
4 SENSORY_RESPONSE NUMERIC No
This column stores the stimulation level when the patient started feeling electric impulses.
5 MOTOR_RESPONSE NUMERIC No
This column stores the stimulation level when the patient started showing muscular reactions.
6 INITIAL_IMPEDANCE NUMERIC No
This column stores the impedence measured prior to applying the catheter to the patient.
7 IMPEDANCE NUMERIC No
This column stores the impedance measured after applying the catheter to the patient.
8 POWER NUMERIC No
This column stores the power level used for ablation.