DOCS_RCVD_OBJECTS
Description:
High level information and metadata about received binary objects.

Primary Key
Column Name Ordinal Position
DOCUMENT_ID 1
CONTACT_DATE_REAL 2
LINE 3

Column Information
Name Type Discontinued?
1 DOCUMENT_ID NUMERIC No
This item stores the Received Document record ID.
2 CONTACT_DATE_REAL FLOAT No
A unique contact date in decimal format. The integer portion of the number indicates the date of contact. The digits after the decimal distinguish different contacts on the same date and are unique for each contact on that date. For example, .00 is the first/only contact, .01 is the second contact, etc.
3 LINE INTEGER No
The line number for the information associated with this contact. Multiple pieces of information can be associated with this contact.
4 CONTACT_DATE DATETIME No
The date of this contact in calendar format.
5 OBJECT_VERSION_IDENT VARCHAR No
The Universal Unique Identifier (UUID) for the binary object.
6 OBJECT_SET_IDENT VARCHAR No
The document set ID that represents a common identifier across all document revisions.
7 OBJECT_EXTERNAL_TYPE VARCHAR No
The type assigned to the object at the sending organization.
8 DOCUMENT_TYPE_GROUP_C_NAME VARCHAR No
The object's type group (I ECT 55330 value)
May contain organization-specific values: No
Category Entries:
Administration
Clinical
Other
Billing
Insurance Card
Insurance-Related Form
Patient Consent
ROI / HIM Consent
Legal Document
Living Will
DNR
Power of Attorney
Legal Letter
Driver's License
Birth Certificate
Death Certificate
Misc Administration
Medication
Medication Order Report
Medication Reconciliation
Prescription List
Radiology and Imaging
Cardiology Imaging
Endoscopy Imaging
OB/GYN Imaging
Dental Imaging
Oncology Imaging
Lab
Procedure
Referral Request / Referral Report
Other Order
Note
Consult Note
H&P Note
Progress Note
Procedure Note
Operative Note
Nurse Note
ED Note
Cardiology Note
GI Note
Oncology Note
Behavior Health Note
Referral Note
Physical Therapy Note
Occupational Therapy Note
OB/GYN Note
Clinical Consent
Procedure Consent
Anesthesia Consent
Surgical Consent
Abortion Consent
Sterilization Consent
Organ Donation Consent
Research Consent
Photographic Image
Wound Care Image
Dermatology Image
Plastic Surgery Image
Flowsheet
Physician Letter
Patient Summary
Discharge Summary
Transfer Summary
Immunization Summary
Labor and Delivery Summary
Physical Therapy Summary
Occupational Therapy Summary
After Visit Summary
Patient Reported Information
Questionnaire
Patient Upload
Patient History
Patient Education and Instructions
Discharge Instructions
Evaluation and Plan
Transplant Evaluation
Risk Assessment
Physical Therapy Treatment Plan
Occupational Therapy Treatment Plan
Oncology Treatment Plan
Case Management
Episode Summary
Surgical Treatment Plan
Misc Clinical
9 OBJECT_MIME_TYPE_C_NAME VARCHAR No
The format used to store the object.
May contain organization-specific values: No
Category Entries:
application/pdf
image/jpeg
image/png
image/bmp
image/tiff
10 OBJECT_PROV VARCHAR No
The name of the provider associated with the object.
11 DICOM_STUDY_UID VARCHAR No
The Digital Imaging and Communications in Medicine (DICOM) Study Instance Unique Identifier (UID) as recorded by the image archive.
12 DICOM_SERIES_UID VARCHAR No
The Digital Imaging and Communications in Medicine (DICOM) Series Instance Unique Identifier (UID) for the imaging series.
13 DICOM_SERIES_SEQ_NUM INTEGER No
The order a series occurs in a Digital Imaging and Communications in Medicine (DICOM) Study Instance
14 DICOM_IMAGE_SEQ_NUM VARCHAR No
The order an image occurs in in a Digital Imaging and Communications in Medicine (DICOM) Series Instant
15 DICOM_MODALITY VARCHAR No
The Digital Imaging and Communications in Medicine (DICOM) modality type as determined by a DICOM image header.
16 OBJECT_DESC VARCHAR No
The description for the object.
17 OBJECT_CREATION_UTC_DTTM DATETIME (UTC) No
The instant the received object was created at the sending organization.
18 OBJECT_RECEIVED_UTC_DTTM DATETIME (UTC) No
The last instant the object was received on a query response.
19 OBJECT_UPDATE_UTC_DTTM DATETIME (UTC) No
The last instant the binary data was changed for the object at the sending organization.
20 CLINICALLY_RELEVANT_UTC_DTTM DATETIME (UTC) No
The most clinically relevant instant for the object at the sending organization.
21 LINKED_EVENT_IDENT VARCHAR No
The event identifier for the encounter document at the sending organization to which the object is related.
22 OBJECT_LOCATION_NAME VARCHAR No
The Care Everywhere location name for the object.
23 OBJECT_LOCATION_IDENT VARCHAR No
The Care Everywhere location ID for the object.
24 OBJECT_HOME_COMMUNITY_IDENT VARCHAR No
Stores the Home Community ID for the object. This item stores the Home Community ID where this object lives. This is used for IHE XDS.b and XCA profiles.
25 OBJECT_SPECIALTY VARCHAR No
The name of the specialty this object is associated with. The specialty listed is the department specialty from the received object.
26 OBJECT_BLOB_TYPE_C_NAME VARCHAR No
Stores the object's blob type (DCS 250) if it was received in a query response.
May contain organization-specific values: Yes
Category Entries:
SCAN
VOICE
ANNOTATION
VIDEO
RAW DEPTH MAP
ECG
SPIRO
HOLTER RESULT
HOLTER ANALYSIS
WAVEFORM STRIP
ESIG
Virtual Authorization
PHOTO
LINK
DOCUMENT
REPORT VIEWER
CHF
DICOM Study
DICOM Series
DICOM Image
TEMPORARY
27 IMG_SLCT_TYPE_C_NAME VARCHAR No
This item stores how this Digital Imaging and Communications in Medicine (DICOM) image was selected by image exchange.
May contain organization-specific values: No
Category Entries:
None
Computer Selected
Key Image