Name |
Type |
Discontinued? |
|
1 |
IMPLANT_ID |
VARCHAR |
No |
|
|
|
The unique identifier (.1 item) for the implant record. |
|
|
2 |
CONTACT_DATE_REAL |
FLOAT |
No |
|
|
|
A unique contact date in decimal format. The integer portion of the number indicates the date of contact. The digits after the decimal distinguish different contacts on the same date and are unique for each contact on that date. For example, .00 is the first/only contact, .01 is the second contact, etc. |
|
|
3 |
PCMKR_PACE_MODE_CMT |
VARCHAR |
No |
|
|
|
Free text comment on the pacing mode of an implanted pacemaker |
|
|
4 |
PCMKR_PV_DELAY_MS |
INTEGER |
No |
|
|
|
P-V delay in milliseconds |
|
|
5 |
PCMKR_AV_DELAY_MS |
INTEGER |
No |
|
|
|
A-V delay in milliseconds |
|
|
6 |
PCMKR_LV_EARLY_YN |
VARCHAR |
No |
|
|
|
Indicate if the left ventricle contraction was early |
May contain organization-specific values: No |
Category Entries: |
No |
Yes |
|
|
7 |
PCMKR_RV_EARLY_YN |
VARCHAR |
No |
|
|
|
Indicate if the right ventricle contraction was early |
The category values for this column were already listed for column: PCMKR_LV_EARLY_YN |
|
|
8 |
PCMKR_VV_DELAY |
INTEGER |
No |
|
|
|
V-V delay in milliseconds |
|
|
9 |
PCMKR_VV_DELAY_CMT |
VARCHAR |
No |
|
|
|
Free text comment on the V-V delay |
|
|
10 |
PCMKR_HYST_C_NAME |
VARCHAR |
No |
|
|
|
Indicate if hysteresis is active |
May contain organization-specific values: Yes |
Category Entries: |
On |
Off |
Not Applicable |
|
|
11 |
PCMKR_HYST_CMT |
VARCHAR |
No |
|
|
|
Free text comment on hysteresis |
|
|
12 |
PCMKR_HYST_A_RATE |
INTEGER |
No |
|
|
|
Indicate the atrial rate for hysteresis |
|
|
13 |
PCMKR_HYST_RATE_C_NAME |
VARCHAR |
No |
|
|
|
Indicate the rate-drop for hysteresis |
The category values for this column were already listed for column: PCMKR_HYST_C_NAME |
|
|
14 |
PCMKR_HYST_RATE_CMT |
VARCHAR |
No |
|
|
|
Free text comment on rate-drop hysteresis |
|
|
15 |
PCMKR_GEN_PACE_CMT |
VARCHAR |
No |
|
|
|
Free text comment on pacing parameters |
|
|
16 |
PCMKR_RV_SENSE_C_NAME |
VARCHAR |
No |
|
|
|
Indicate the sensing polarity of the RV lead |
May contain organization-specific values: Yes |
Category Entries: |
Bipolar |
Unipolar |
|
|
17 |
PCMKR_ATR_SENSE_C_NAME |
VARCHAR |
No |
|
|
|
Indicate the sensing polarity of the atrial lead |
The category values for this column were already listed for column: PCMKR_RV_SENSE_C_NAME |
|
|
18 |
PCMKR_LV_SENSE_C_NAME |
VARCHAR |
No |
|
|
|
Indicate the sensing polarity of the LV lead |
The category values for this column were already listed for column: PCMKR_RV_SENSE_C_NAME |
|
|
19 |
PCMKR_RV_PACE_C_NAME |
VARCHAR |
No |
|
|
|
Indicate the pacing polarity of the RV lead |
The category values for this column were already listed for column: PCMKR_RV_SENSE_C_NAME |
|
|
20 |
PCMKR_ATR_PACE_C_NAME |
VARCHAR |
No |
|
|
|
Indicate the pacing polarity of the atrial lead |
The category values for this column were already listed for column: PCMKR_RV_SENSE_C_NAME |
|
|
21 |
PCMKR_LV_PACE_C_NAME |
VARCHAR |
No |
|
|
|
Indicate the pacing polarity of the LV lead |
The category values for this column were already listed for column: PCMKR_RV_SENSE_C_NAME |
|
|
22 |
PCMKR_POLARITY_CMT |
VARCHAR |
No |
|
|
|
Free text comment on lead polarities |
|
|
23 |
PCMKR_PR_AMPLITUDE |
INTEGER |
No |
|
|
|
Indicate the amplitude of the P/R wave in millivolts |
|
|
24 |
PCMKR_MODE_SWTCH_C_NAME |
VARCHAR |
No |
|
|
|
Indicate if mode switching is active |
The category values for this column were already listed for column: PCMKR_HYST_C_NAME |
|
|
25 |
PCMKR_MD_SWTCH_CMT |
VARCHAR |
No |
|
|
|
Free text comment on mode switching |
|
|
26 |
PCMKR_A_RATE_SWTCH |
INTEGER |
No |
|
|
|
Indicate the atrial rate for mode switching |
|
|
27 |
DENT_PLATFRM_SIZE_C_NAME |
VARCHAR |
No |
|
|
|
Dental implant platform size. |
May contain organization-specific values: No |
Category Entries: |
Regular |
Narrow |
Wide |
Other |
|
|
28 |
DENT_DRILL_PROT_C_NAME |
VARCHAR |
No |
|
|
|
Dental implant drill protocol. |
May contain organization-specific values: No |
Category Entries: |
Conventional |
Simplified |
|
|
29 |
DENT_CONNECT_TYPE_C_NAME |
VARCHAR |
No |
|
|
|
Dental implant connection type. |
May contain organization-specific values: No |
Category Entries: |
Internal |
External |
|
|
30 |
DENT_COLLAR_SURF_C_NAME |
VARCHAR |
No |
|
|
|
Dental implant collar surface. |
May contain organization-specific values: No |
Category Entries: |
Rough |
Polished |
|
|
31 |
DENT_IMP_TAPER_C_NAME |
VARCHAR |
No |
|
|
|
Dental implant taper. |
May contain organization-specific values: No |
Category Entries: |
Tapered |
Straight Wall |
|
|
32 |
DENT_DIAMETER |
INTEGER |
No |
|
|
|
|
33 |
DENT_IMP_INS_TORQUE |
INTEGER |
No |
|
|
|
Dental implant insertion torque. |
|
|
34 |
DENT_IMP_SITE_RECORD_ID |
NUMERIC |
No |
|
|
|
|
35 |
DENT_IMP_SITE_RECORD_ID_RECORD_NAME |
VARCHAR |
No |
|
|
|
|
36 |
DENT_IMP_CODE_PROC_ID_PROC_NAME |
VARCHAR |
No |
|
|
|
The name of each procedure. |
|
|
37 |
DENT_IMP_BILL_PROV_ID_PROV_NAME |
VARCHAR |
No |
|
|
|
The name of the service provider. This item may be hidden in a public view of the CLARITY_SER table. |
|
|
38 |
DENT_IMP_AUTH_PROV_ID_PROV_NAME |
VARCHAR |
No |
|
|
|
The name of the service provider. This item may be hidden in a public view of the CLARITY_SER table. |
|
|
39 |
DENT_GUIDE_USED_YN |
VARCHAR |
No |
|
|
|
Stores whether a guide was used to place a dental implant. |
The category values for this column were already listed for column: PCMKR_LV_EARLY_YN |
|
|