OR_LNLG_ESU
Description:
This table contains Electro Surgery Units information for the surgical log (ORL).

Primary Key
Column Name Ordinal Position
RECORD_ID 1

Column Information
Name Type Discontinued?
1 RECORD_ID VARCHAR No
The unique ID of the line record.
2 ELECT_SURG_DEV_ID_PROV_NAME VARCHAR No
The name of the service provider. This item may be hidden in a public view of the CLARITY_SER table.
3 ELCT_SRG_MOD_TYP_C_NAME VARCHAR No
The ESU device mode type.
May contain organization-specific values: Yes
Category Entries:
Monopolar
Bipolar
4 ELECT_SURG_LOC_C_NAME VARCHAR No
The location at which the ESU was applied.
May contain organization-specific values: Yes
5 ELECT_SURG_LATER_C_NAME VARCHAR No
The laterality of the location.
May contain organization-specific values: Yes
Category Entries:
Left
Right
Bilateral
N/A
Default
6 ESD_TYPE_C_NAME VARCHAR No
The ESU device type.
May contain organization-specific values: Yes
7 ELECT_SURG_COAG_SE NUMERIC No
The ESU coagulation settings.
8 ELECT_SURG_CUT_SET NUMERIC No
The ESU cut settings.
9 ELECT_SURG_BSET_C_NAME VARCHAR No
Stores the blend settings for the Electro Surgery Device.
May contain organization-specific values: Yes
No Entries Defined
10 ELECT_SURG_COAG_HGH NUMERIC No
Documents the high coagulation setting of a particular electrosurgical device.
11 ELECT_SURG_CUT_HIGH NUMERIC No
Documents the high cut setting of a particular electrosurgical device.
12 ELECT_SURG_GPAPP_ID_PROV_NAME VARCHAR No
The name of the service provider. This item may be hidden in a public view of the CLARITY_SER table.
13 ELECT_SURG_PAD_LOT VARCHAR No
Documents the lot number of the ESU's grounding pad.
14 GROUND_PAD_EXP_DT DATETIME No
This item stores the expiration date for an ESU grounding pad.
15 BIPOLAR_SETTING NUMERIC No
This item stores the bipolar setting for an Electro Surgery Device. This is the voltage.
16 MONO_CUT_SETTING_C_NAME VARCHAR No
The monopolar cut setting category number for the electro surgery unit.
May contain organization-specific values: Yes
No Entries Defined
17 MONO_COAG_SETTING_C_NAME VARCHAR No
The monopolar coagulation setting category number for the electro surgery unit.
May contain organization-specific values: Yes
No Entries Defined
18 ESU_COAG_WATTAGE INTEGER No
Stores information about the wattage for the coagulation setting of the electro surgery unit.
19 ESU_CUT_WATTAGE INTEGER No
Stores information about the wattage for the cut setting of the electro surgery unit.
20 ESU_BIPOLAR_WATTAG INTEGER No
Stores information about the wattage for the bipolar setting of the electro surgery unit.
21 LIGASURE_ONE_LOW_C_NAME VARCHAR No
The category number for the Ligasure 1 Low item. This is usually the same as the internal ID. If you use IntraConnect, this is the Community ID (CID).
May contain organization-specific values: Yes
No Entries Defined
22 LIGASURE_ONE_HIGH_C_NAME VARCHAR No
The category number for the Ligasure 1 High item. This is usually the same as the internal ID. If you use IntraConnect, this is the Community ID (CID).
May contain organization-specific values: Yes
No Entries Defined
23 LIGASURE_TWO_LOW_C_NAME VARCHAR No
The category number for the Ligasure 2 Low item. This is usually the same as the internal ID. If you use IntraConnect, this is the Community ID (CID).
May contain organization-specific values: Yes
No Entries Defined
24 LIGASURE_TWO_HIGH_C_NAME VARCHAR No
The category number for the Ligasure 2 High item. This is usually the same as the internal ID. If you use IntraConnect, this is the Community ID (CID).
May contain organization-specific values: Yes
No Entries Defined
25 BIPOLAR_COAG_LOW INTEGER No
The low bipolar coagulation setting for the electro surgery unit.
26 BIPOLAR_COAG_HIGH INTEGER No
The high bipolar coagulation setting for the electro surgery unit (ESU).
27 BIPOLAR_SETTINGS_C_NAME VARCHAR No
The category number for the Bipolar Output Settings item.
May contain organization-specific values: Yes
No Entries Defined
28 GROUND_PAD_SER_NUM VARCHAR No
This item stores the serial number of the ESU grounding pad.
29 ELECT_SURG_PRESET_C_NAME VARCHAR No
Store settings for ESU device.
May contain organization-specific values: Yes
No Entries Defined
30 ESU_GAS_FLOW_HIGH NUMERIC No
The high gas flow rate for the electro surgery unit.
31 ESU_GAS_FLOW_LOW NUMERIC No
The low gas flow rate for the electro surgery unit.
32 ESU_COAG_SETTING NUMERIC No
Item to document medium setting of ESU machines.
33 ESU_CUT_SETTING NUMERIC No
Item to document medium cut setting of ESU machines.
34 ESU_MODULATION INTEGER No
This item stores the numerical modulation setting for Electro Surgical Equipment.