OR_LNLG_LASERS
Description:
This table contains the laser information for the surgical log (ORL).

Primary Key
Column Name Ordinal Position
RECORD_ID 1

Column Information
Name Type Discontinued?
1 RECORD_ID VARCHAR No
The unique ID of the line record.
2 LASER_DEVICE_ID_PROV_NAME VARCHAR No
The name of the service provider. This item may be hidden in a public view of the CLARITY_SER table.
3 LASER_TOTAL_WATTS NUMERIC No
Total watts used for this laser device in this log.
4 LASER_TOTAL_PULSES NUMERIC No
The total pulses used for this laser device in this log.
5 LASER_TYPE_C_NAME VARCHAR No
The number populated in this column points to a particular laser type.
May contain organization-specific values: Yes
6 LASER_LO_SET NUMERIC No
The low setting for the laser.
7 LASER_HI_SET NUMERIC No
The high setting for the laser.
8 LASER_MODE_C_NAME VARCHAR No
The operation mode category number for this laser.
May contain organization-specific values: Yes
9 LASER_PULSE_HI_FRE NUMERIC No
The high pulse frequency of the laser.
10 LASER_PULSE_LO_FRE NUMERIC No
The low pulse frequency of the laser.
11 LASER_FIBER_TYPE_C_NAME VARCHAR No
The number populated in this column points to a particular fiber type used in this laser.
May contain organization-specific values: Yes
No Entries Defined
12 LASER_TOT_JOULES NUMERIC No
Stores the total joules used for the Laser.
13 LASER_WAVELENGTH NUMERIC No
Stores the wavelength of the Laser.
14 LASER_TOTAL_TIME INTEGER No
Stores the total time that the laser was used.
15 LASER_FIBER_SIZE NUMERIC No
The fiber size of the laser.
16 LASER_PLUME_EXCV_C_NAME VARCHAR No
The number populated in this column points to a particular evacuation method for plumes of smoke generated from laser cauterization.
May contain organization-specific values: Yes
No Entries Defined
17 LASER_OPERATOR_ID_PROV_NAME VARCHAR No
The name of the service provider. This item may be hidden in a public view of the CLARITY_SER table.
18 LASER_POWER_UNIT_C_NAME VARCHAR No
The power unit category number for the power measurements documented on this laser.
May contain organization-specific values: Yes
Category Entries:
Watts
Milliwatts
Microwatts
Nanowatts
19 LASER_INTERVAL NUMERIC No
The number of seconds for the interval of this laser.
20 LASER_DURATION NUMERIC No
The number of seconds for the duration of this laser.
21 LASER_DELIV_METH_C_NAME VARCHAR No
The delivery method category number for this laser.
May contain organization-specific values: Yes
No Entries Defined
22 LASER_HANDPC_TYP_C_NAME VARCHAR No
The number populated in this column points to the type of hand piece used for operating the laser.
May contain organization-specific values: Yes
No Entries Defined
23 LASER_HANDPC_SIZE NUMERIC No
The size in millimeters of the hand piece used while operating the laser device.
24 LASER_MICRO_TYP_C_NAME VARCHAR No
The number populated in this column points to the type of microscope used for operating the laser.
May contain organization-specific values: Yes
No Entries Defined
25 LASER_MICRO_SIZE NUMERIC No
The size (in millimeters) of the microscope used while operating the laser device.
26 LASER_HEADPC_TYP_C_NAME VARCHAR No
The number populated in this column points to the type of head piece used for operating the laser.
May contain organization-specific values: Yes
No Entries Defined
27 LASER_HEADPC_SIZE NUMERIC No
The size (in millimeters) of the head piece used while operating the laser device.
28 LASER_FIBER_LOT_NUM VARCHAR No
The lot number of the laser fiber.
29 LASER_ENERGY_UNIT_C_NAME VARCHAR No
The energy unit category number for the energy measurements documented on this laser.
May contain organization-specific values: Yes
Category Entries:
Millijoules
Joules
Kilojoules
Calories
Kilocalories
British Thermal Units
Kilowatt Hours
Microjoules
Nanojoules
Megajoules
Gigajoules
30 LSC_FIO2_LEVEL_OK_YN_NAME VARCHAR No
The FiO2 level category number for the laser safety checklist.
May contain organization-specific values: Yes
Category Entries:
Yes
No
31 LSC_FIRE_EXTINGSR_C_NAME VARCHAR No
The number populated in this column indicates whether a fire extinguisher was available: 11 - Yes , 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
May contain organization-specific values: No
Category Entries:
No (Old)
Yes (Old)
N/A (Old)
Yes
No
N/A
32 LSC_FIRE_REDUCTN_YN_NAME VARCHAR No
The fire risk reduction strategy category number for the laser safety checklist.
May contain organization-specific values: Yes
Category Entries:
Yes
No
33 LSC_FIRE_SAFE_DG_C_NAME VARCHAR No
The number populated in this column indicates whether fire-retardant drapes and gowns were used: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
34 LSC_LSR_EVAC_POS_C_NAME VARCHAR No
The number populated in this column indicates whether the smoke evacuator was positioned during laser use: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
35 LSC_ET_TUBE_USED_C_NAME VARCHAR No
The number populated in this column indicates whether an endotracheal tube was used during laser use: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
36 LSC_MOIST_ITEMS_C_NAME VARCHAR No
The number populated in this column indicates whether moistened towels, gauze, and sponges were available for safety during laser use: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
37 LSC_BASIN_WATER_C_NAME VARCHAR No
The number populated in this column indicates whether a water-filled basin was available for safety during laser use: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
38 LSC_PAT_EYE_PROT_C_NAME VARCHAR No
The number populated in this column indicates whether the patient's eyes were protected while the laser was in use: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
39 LSC_STAFF_EYEWEAR_C_NAME VARCHAR No
The number populated in this column indicates whether the staff's eyes were protected while the laser was in use: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
40 LSC_PHYS_EYEWEAR_C_NAME VARCHAR No
The number populated in this column indicates whether the physician's eyes were protected while the laser was in use: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
41 LSC_EYEWEAR_AVAIL_C_NAME VARCHAR No
The number populated in this column indicates whether protective eyewear was available: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
42 LSC_NO_EYEWEAR_RSN VARCHAR No
The column displays the reason for the lack of protective eyewear documented by the circulating nurse.
43 LSC_STAFF_MASK_C_NAME VARCHAR No
The number populated in this column indicates whether the staff used protective masks while the laser was in use: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
44 LSC_MASK_AVAIL_C_NAME VARCHAR No
The number populated in this column indicates whether protective masks were available: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
45 LSC_RCTL_PACK_RMV_C_NAME VARCHAR No
The number populated in this column indicates whether rectal packing was removed: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
46 LSC_SIGNS_HUNG_C_NAME VARCHAR No
The number populated in this column indicates whether appropriate danger signs were hung on doors: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
47 LSC_EYEWEAR_HUNG_C_NAME VARCHAR No
The number populated in this column indicates whether protective eyewear was hung on doors available for use: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
48 LSC_WINDOWS_COVRD_C_NAME VARCHAR No
The number populated in this column indicates whether the windows were covered while laser was in use: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
49 LSC_STERILE_FLUID_C_NAME VARCHAR No
The number populated in this column indicates whether sterile water and other sterile fluids were available: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
50 LSC_N2O_LEVEL_OK_YN_NAME VARCHAR No
The N2O level category number for the laser safety checklist.
May contain organization-specific values: Yes
Category Entries:
Yes
No
51 LSC_DOOR_LOCKED_C_NAME VARCHAR No
The number populated in this column indicates whether the door was locked for safety while the laser was in use: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
52 LSC_FIBER_CHECKED_C_NAME VARCHAR No
The number populated in this column indicates whether the laser fiber integrity was checked: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
53 LSC_FILTER_CABLE_C_NAME VARCHAR No
The number populated in this column indicates whether the microscope filter cable was positioned appropriately: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
54 LSC_MICROSCP_FLTR_C_NAME VARCHAR No
The number populated in this column indicates whether there was a filter on the microscope: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
55 LSC_NON_REFLCTVTY_C_NAME VARCHAR No
The number populated in this column indicates whether the instruments were checked for non-reflectivity: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
56 LSC_LASER_TESTED_C_NAME VARCHAR No
The number populated in this column indicates whether the laser was test-fired prior to use: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
57 LSC_KEY_RETURNED_C_NAME VARCHAR No
The number populated in this column indicates whether the laser key was returned: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
58 LSC_LASER_STANDBY_C_NAME VARCHAR No
The number populated in this column indicates whether the laser was in standby mode when not in use: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
59 LSC_PEDAL_POSITND_C_NAME VARCHAR No
The number populated in this column indicates whether the laser pedal position was appropriate: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
60 LSC_MICROSCP_CHKD_C_NAME VARCHAR No
The number populated in this column indicates whether the microscope was inspected prior to use: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
61 LSC_SELF_CHECK_YN_NAME VARCHAR No
The number populated in this column indicates whether the laser self-check was performed: 1 - Yes, 2 - No.
May contain organization-specific values: Yes
Category Entries:
Yes
No
62 LSC_BEAM_PATTERN_C_NAME VARCHAR No
The number populated in this column indicates whether the laser beam pattern was checked: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
63 LSC_FIBER_CALIB_C_NAME VARCHAR No
The number populated in this column indicates whether the laser fiber was calibrated: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
64 LSC_FIBER_EXPIRE_DT DATETIME No
The column displays the expiration date of the fiber.
65 LSC_FIBER_LOT_NUM VARCHAR No
The column displays the lot number of the laser fiber.
66 LSC_CIRCUIT_POS_C_NAME VARCHAR No
The number populated in this column indicates whether the circuit breaker was in the correct position: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
67 LSC_CORDS_PLUGGED_C_NAME VARCHAR No
The number populated in this column indicates whether the cords were plugged into appropriate outlets: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
68 LSC_DELIVERY_SYS_C_NAME VARCHAR No
The number populated in this column indicates whether the delivery system was properly connected: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
69 LSC_CORD_CONDTION_C_NAME VARCHAR No
The number populated in this column indicates whether the electrical cords were in good condition: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
70 LSC_LASER_REGION_C_NAME VARCHAR No
The number populated in this column points to a particular operative region to which the laser was applied.
May contain organization-specific values: Yes
71 LSC_GAS_ON_C_NAME VARCHAR No
The number populated in this column indicates whether the laser gas was turned on appropriately: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
72 LSC_GAS_OFF_C_NAME VARCHAR No
The number populated in this column indicates whether the laser gas was turned off appropriately: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
73 LSC_PE_EYE_PROT_C_NAME VARCHAR No
The number populated in this column indicates whether the patient was educated about laser eye protection: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
74 LSC_PE_MOVEMENT_C_NAME VARCHAR No
The number populated in this column indicates whether the patient was educated about not moving during the procedure: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
75 LSC_PE_TALKING_C_NAME VARCHAR No
The number populated in this column indicates, for facial procedures, whether the patient was educated about not talking during the procedure: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
76 LSC_PE_NOISE_C_NAME VARCHAR No
The number populated in this column indicates whether the patient was educated about the noises that may occur during the procedure: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
77 LSC_PE_DRAPES_C_NAME VARCHAR No
The number populated in this column indicates whether the patient was educated about the special drapings: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
78 LSC_ASST_AVAIL_C_NAME VARCHAR No
The number populated in this column indicates whether a laser assistant was available while the laser was in use: 11 - Yes, 12 - No, 13 - Not Applicable (For older records, the column may return 0 for No, 1 for Yes, and 3 for Not Applicable).
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
79 LASER_LATERALITY_C_NAME VARCHAR No
This item stores laterality for a laser device.
May contain organization-specific values: Yes
Category Entries:
Left
Right
Bilateral
N/A
Default
80 LSC_TIMEOUT_BEF_C_NAME VARCHAR No
Documenting this item verifies that a timeout was done by all members of the surgical team prior to laser activation.
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
81 LSC_EMERG_REVD_C_NAME VARCHAR No
This item verifies that the laser emergency stop procedure was reviewed before use.
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
82 LSC_PWR_SET_COMM_C_NAME VARCHAR No
Documenting this item verifies that the laser power settings were communicated to the surgeon prior to its use.
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
83 LSC_TIPS_RETURN_C_NAME VARCHAR No
Document if laser tips were returned as part of laser checklist.
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
84 LSC_CLN_AFTER_USE_C_NAME VARCHAR No
The value populated in this column indicates whether a laser was cleaned after use in a procedure.
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
85 LSC_STR_AFTER_USE_C_NAME VARCHAR No
The value populated in this column indicates whether a laser was stored properly after use in a procedure.
The category values for this column were already listed for column: LSC_FIRE_EXTINGSR_C_NAME
86 LASER_ENERGY_LOW NUMERIC No
The initial/low energy setting for the laser in chosen units.
87 LASER_ENERGY_HIGH NUMERIC No
The final/high energy setting for the laser in chosen units.
88 LASER_CPG_DENSITY NUMERIC No
The density of the CPG laser.
89 LASER_CPG_PATTERN NUMERIC No
The pattern of the CPG laser.
90 LASER_CPG_SIZE NUMERIC No
The size of the CPG laser.
91 LASER_DISTANCE NUMERIC No
The distance between the laser fiber and the laser application point. This information is required for some vascular surgery research projects.
92 LASER_LENGTH_TREATD NUMERIC No
The length of the area treated by the laser. This information is required for some vascular surgery research projects.
93 LASER_PULSE_DUR_LOW NUMERIC No
Stores the low end of the pulse duration range for the laser.
94 LASER_PULSE_DUR_HI NUMERIC No
Stores the high end of the pulse duration range for the laser.
95 LASER_AVG_POWER NUMERIC No
This item is used to document laser average power.
96 LASER_PULSE_FREQ_UNIT_C_NAME VARCHAR No
The laser pulse frequency unit.
May contain organization-specific values: Yes
No Entries Defined
97 LASER_ENERGY_PER_PULSE_UNIT_C_NAME VARCHAR No
The laser energy per pulse unit.
May contain organization-specific values: Yes
No Entries Defined
98 LASER_PULSE_DURATION_UNIT_C_NAME VARCHAR No
The laser pulse duration unit.
May contain organization-specific values: Yes
No Entries Defined