Name |
Type |
Discontinued? |
|
| 1 |
RECORD_ID |
VARCHAR |
No |
|
|
|
| The unique ID of the line record. |
|
|
| 2 |
OTHER_EQUIP_ID_PROV_NAME |
VARCHAR |
No |
|
|
|
| The name of the service provider. This item may be hidden in a public view of the CLARITY_SER table. |
|
|
| 3 |
OTHER_EQUIP_SET_T_NAME |
VARCHAR |
No |
|
|
|
| The setting type for the other equipment. |
| May contain organization-specific values: Yes |
|
|
| 4 |
OTHER_EQUIP_SET_HI |
NUMERIC |
No |
|
|
|
| The high setting for the equipment. |
|
|
| 5 |
OTHER_EQUIP_SET_LO |
NUMERIC |
No |
|
|
|
| The low setting for the equipment |
|
|
| 6 |
OTH_EQUIP_TYPE_C_NAME |
VARCHAR |
No |
|
|
|
| The type of the other equipment. |
| May contain organization-specific values: Yes |
|
|
| 7 |
HYST_PUMP_ID_PROV_NAME |
VARCHAR |
No |
|
|
|
| The name of the service provider. This item may be hidden in a public view of the CLARITY_SER table. |
|
|
| 8 |
HYST_PUMP_PRESSURE |
NUMERIC |
No |
|
|
|
| The pressure setting (mmHg) for the hysteroscopy pump. |
|
|
| 9 |
HYST_PUMP_DEFICIT |
NUMERIC |
No |
|
|
|
| The deficit setting (mL) for the hysteroscopy pump. |
|
|
| 10 |
HYST_PUMP_T_INFLOW |
NUMERIC |
No |
|
|
|
| The total inflow setting (mL) for the hysteroscopy pump. |
|
|
| 11 |
LAP_SCN_ID_PROV_NAME |
VARCHAR |
No |
|
|
|
| The name of the service provider. This item may be hidden in a public view of the CLARITY_SER table. |
|
|
| 12 |
CELL_SAVER_ID_PROV_NAME |
VARCHAR |
No |
|
|
|
| The name of the service provider. This item may be hidden in a public view of the CLARITY_SER table. |
|
|
| 13 |
CELL_SAVER_NUM |
VARCHAR |
No |
|
|
|
| The numeric or alphanumeric identifier for the cell saver machine. |
|
|
| 14 |
HYST_PUMP_ALM_SE_YN |
VARCHAR |
No |
|
|
|
| Indicates whether the hysteroscopy pump alarm settings are within limits. Y indicates that the alarm settings are within limits. N indicates that the alarm settings are not within limits. |
| May contain organization-specific values: No |
| Category Entries: |
| No |
| Yes |
|
|
| 15 |
LAP_SCN_PRERD_C_NAME |
VARCHAR |
No |
|
|
|
| The category title of the pre-op reading (intact/compromised/NA) for the laparoscopic instrument scan. |
| May contain organization-specific values: Yes |
| Category Entries: |
| Intact |
| Compromised |
| N/A |
|
|
| 16 |
LAP_SCN_POSTRD_C_NAME |
VARCHAR |
No |
|
|
|
| The category title of the post-op reading (intact/compromised/NA) for the laparoscopic instrument scan. |
| The category values for this column were already listed for column: LAP_SCN_PRERD_C_NAME |
|
|
| 17 |
OTHER_EQUIP_LAT_C_NAME |
VARCHAR |
No |
|
|
|
| This item stores laterality for other equipment. |
| May contain organization-specific values: Yes |
| Category Entries: |
| Left |
| Right |
| Bilateral |
| N/A |
| Default |
|
|
| 18 |
OTHER_EQUIP_CAV_WID |
NUMERIC |
No |
|
|
|
| Document the cavity width measurement, as measured by other equipment type. |
|
|
| 19 |
OTHER_EQUIP_CAV_LEN |
NUMERIC |
No |
|
|
|
| Document the cavity length measurement, as measured by other equipment type. |
|
|
| 20 |
OTHER_EQUIP_PWR_LOW |
INTEGER |
No |
|
|
|
| Document the low power for other equipment type. |
|
|
| 21 |
OTHER_EQUIP_PWR_HI |
INTEGER |
No |
|
|
|
| Document the high power for other equipment type. |
|
|
| 22 |
OTH_EQUIP_PWR_UNI_C_NAME |
VARCHAR |
No |
|
|
|
| Document the power unit for other equipment type. |
| May contain organization-specific values: Yes |
| No Entries Defined |
|
|
| 23 |
HYST_PUMP_T_OUTFLOW |
NUMERIC |
No |
|
|
|
| The total outflow setting (mL) for the hysteroscopy pump. |
|
|
| 24 |
CELL_SVR_VOL_PROC |
INTEGER |
No |
|
|
|
| This column contains information about the number of milliliters of blood processed during surgery. |
|
|
| 25 |
CELL_SVR_VOL_REINFU |
INTEGER |
No |
|
|
|
| This column contains information about the number of milliliters of blood reinfused during surgery. |
|
|
| 26 |
NUMBER_OF_CYCLES |
INTEGER |
No |
|
|
|
| This item stores the number of cycles setting for a piece of ablation equipment. |
|
|
| 27 |
NUMBER_OF_SITES |
INTEGER |
No |
|
|
|
| This item stores the number of ablation sites to which this piece of equipment was applied. |
|
|
| 28 |
TEMPERATURE |
NUMERIC |
No |
|
|
|
| This item stores the temperature for a piece of ablation equipment. |
|
|
| 29 |
OTHER_EQUIP_VOLUME |
NUMERIC |
No |
|
|
|
| This item stores the volume, as measured by other equipment type. |
|
|
| 30 |
OTHER_EQUIP_SER_NUM |
NUMERIC |
No |
|
|
|
| This item stores the serial number of other equipment type. |
|
|
| 31 |
AVERAGE_POWER |
NUMERIC |
No |
|
|
|
|
| 32 |
OTHER_EQUIP_SOUNDING_LEN |
NUMERIC |
No |
|
|
|
| This column stores the sounding length measurement in centimeters, as measured by a piece of equipment. |
|
|
| 33 |
OTHER_EQUIP_SETTING_ADDITIONAL |
NUMERIC |
No |
|
|
|
| This column stores additional equipment settings. |
|
|
| 34 |
CELL_SVR_VOL_NOT_PROCESSED |
INTEGER |
No |
|
|
|
| The milliliters of blood not processed. |
|
|
| 35 |
CELL_SVR_VOL_WASTED |
INTEGER |
No |
|
|
|
| The milliliters of blood wasted. |
|
|
| 36 |
CELL_SVR_IRRIGATION_VOL |
NUMERIC |
No |
|
|
|
| This column stores the Irrigation volume used for cell saver. |
|
|
| 37 |
CELL_SVR_ANTICOAG_VOL |
NUMERIC |
No |
|
|
|
| This column stores the anti-coagulant volume used for cell saver. |
|
|
| 38 |
IMPLANT_ON_CART_YN |
VARCHAR |
No |
|
|
|
| If there was an implant not on the cart. Used for comprehensive steam sterilization (IUSS) documentation. |
| The category values for this column were already listed for column: HYST_PUMP_ALM_SE_YN |
|
|