TRANSPLANT_ORG_ECS
Description:
This table contains information about a transplant patient's willingness to accept organs from donors meeting various criteria. Each line represents a change in the documentation about the patient's willingness to accept organs from donors meeting various criteria.

Primary Key
Column Name Ordinal Position
SUMMARY_BLOCK_ID 1
LINE 2

Column Information
Name Type Discontinued?
1 SUMMARY_BLOCK_ID NUMERIC No
The unique ID of the episode of care record.
2 LINE INTEGER No
Each line identifies a change to the type organ accepted selection.
3 TX_HCV_YN VARCHAR No
Whether or not the patient will accept an hepatitis C (HCV) positive organ.
May contain organization-specific values: No
Category Entries:
Yes
No
4 TX_HBV_YN VARCHAR No
Whether or not the patient will accept a hepatitis B (HBV) positive organ.
The category values for this column were already listed for column: TX_HCV_YN
5 TX_ECD_YN VARCHAR No
Whether or not the patient will accept an organ from an expanded criteria donor.
The category values for this column were already listed for column: TX_HCV_YN
6 TX_ECD_UPD_USER_ID VARCHAR No
The user who updated patient's donor criteria.
7 TX_ECD_UPD_USER_ID_NAME VARCHAR No
The name of the user record. This name may be hidden.
8 TX_ECD_UPD_INST DATETIME (Local) No
The instant when patient's donor criteria were documented.
9 TX_HCV_REASON_C_NAME VARCHAR No
The category number for the reason for accepting or not accepting an organ from a hepatitis C (HCV) positive donor. This category number is usually the same as the internal ID. If you use IntraConnect, this is the Community ID (CID).
May contain organization-specific values: Yes
10 TX_HBV_REASON_C_NAME VARCHAR No
The category number for the reason for accepting or not accepting an organ from a hepatitis B (HBV) positive donor. This category number is usually the same as the internal ID. If you use IntraConnect, this is the Community ID (CID).
May contain organization-specific values: Yes
11 TX_ECD_REASON_C_NAME VARCHAR No
The category number for the reason for accepting or not accepting an organ from an expanded criteria donor. This category number is usually the same as the internal ID. If you use IntraConnect, this is the Community ID (CID).
May contain organization-specific values: Yes
12 TX_DOC_VERIFIER_ID VARCHAR No
User who verifies the donor organ criteria
13 TX_DOC_VERIFIER_ID_NAME VARCHAR No
The name of the user record. This name may be hidden.
14 TX_DOC_VERIFY_INST DATETIME (Local) No
Date the donor organ criteria was verified
15 TX_CROSSMATCH_YN VARCHAR No
Does transplant require a crossmatch
The category values for this column were already listed for column: TX_HCV_YN
16 TX_XMATCH_REASON_C_NAME VARCHAR No
The category number for the reason the organ does or does not need crossmatch testing performed. This category number is usually the same as the internal ID. If you use IntraConnect, this is the Community ID (CID).
May contain organization-specific values: Yes
17 TX_ANTIGENS_YN VARCHAR No
Does the transplant have unacceptable antigens
The category values for this column were already listed for column: TX_HCV_YN
18 TX_ANTIGEN_REASON_C_NAME VARCHAR No
The category number for the reason for the patient's unacceptable antigens. This category number is usually the same as the internal ID. If you use IntraConnect, this is the Community ID (CID).
May contain organization-specific values: Yes
19 TX_DCD_YN VARCHAR No
Whether the recipient will accept an organ from a donor who died from cardiac death.
The category values for this column were already listed for column: TX_HCV_YN
20 TX_DCD_REASON_C_NAME VARCHAR No
The reason for accepting or not accepting a donation after cardiac death.
May contain organization-specific values: Yes
No Entries Defined
21 MIN_DNR_WEIGHT NUMERIC No
Minimum acceptable donor weight
22 MAX_DNR_WEIGHT NUMERIC No
Maximum acceptable donor weight
23 CDC_HIGH_RISK_YN VARCHAR No
Indicates whether the patient will accept an organ from a donor that has risk factors for blood-borne disease transmission.
The category values for this column were already listed for column: TX_HCV_YN
24 CDC_REASON_C_NAME VARCHAR No
The reason a patient will or will not accept an organ from a donor that has risk factors for blood-borne disease transmission.
May contain organization-specific values: Yes
No Entries Defined
25 SEGMENTAL_LIVER_YN VARCHAR No
Indicates whether the patient will accept a segmental liver from a donor.
The category values for this column were already listed for column: TX_HCV_YN
26 SEG_LVR_REASON_C_NAME VARCHAR No
The reason a patient will or will not accept a segmental liver as a donor organ.
May contain organization-specific values: Yes
No Entries Defined